THERMOLUMINESCENT DETECTORS FOR SURVEILLANCE STUDIES OF RADIATION EXPOSURE OF THE POPULATION
Рубрики: CHEMICAL SCIENCES
Аннотация и ключевые слова
Аннотация (русский):
Luminescent glow occurring in a substance exposed to ionizing radiation (IR) in the process of heating, thermoluminescence (TL) is now an effective method of registration of radiation-absorbed doses. It is important to be aware that the correct absorbed dose when exposed to mixed radiation with unknown characteristics is determined in the material of detector as well as in materials similar in composition (Z eff) and density [1-3]. In this connection, it is expedient to use different types of detectors for solution of different dosimetric problems. This study gives a comparison of the performance characteristics of TLD-K thermoluminescent detectors [4, 5], made of sodium silicate glass ceramic with the characteristics of IR detectors made of luminophors based on lithium fluoride monocrystals containing impurities of titanium and magnesium (TLD -100) [6, 7] and an anion of defective aluminum oxide (TLD-500) [8-11] widely used in thermoluminescence dosimetry. Comparison of a number of parameters that are relevant to the use of detectors in dosimetric monitoring of environment favors TLD-K detectors. The studies were carried out on the territory of the Kemerovo region.

Ключевые слова:
Thermoluminescence, detectors, ionizing radiation, absorbed dose, environment
Текст
Текст произведения (PDF): Читать Скачать

Different kinds of thermoluminescence detectors (TLDs) can provide determination of absorbed doses in different environments, including tissues of human organism. The advantage of thermoluminescent dosimeters over other ones for determination of absorbed doses of ionizing radiation (IR) lies in high sensitivity of thermoluminescent detectors to different types of radiation, in integral character of dose accumulation, small sizes, and quite low cost price. Based on the above, one can conclude that TLDs can be effectively used for studying the real topography of radiation fields, for medical application of ionizing radiation and for radioecological monitoring of territories while controlling radiation effects in the environment. In dosimetry, the most widespread thermolumines- cent detectors among the staff who work with IR [6-8] are the ones based on LiF. This is due to the affinity between the effective atomic number of LiF on photoemission (Zeff - 8.65) and the effective atomic number of the human soft tissue (Zeff - 7.8). Substances with identical effective index numbers Z have comparable mass attenuation coefficients μ/ρ, where μ is the linear absorption coefficient, cm-1, ρ is the density, g/cm3. For photon absorption radiation IR is described by the following equation [1, 3, 13]: N = N 0 e -m l = N 0 e- ( m / r ) rl (1) Where N0 - is the number of g-quanta, included in absorber layer, N is the number of g-quanta, passed through the absorber, g/cm3, m/ρ is the mass absorption coefficient, cm2/g, l is the absorber layer thickness, cm, rl is the layer thickness, g/cm2. The mass absorption coefficient values of different substances are close for high-energy radiation and varied widely for low-energy photon radiation. For high- energy radiation, absorption is determined mainly by the absorber thickness, g/cm2, whereas for low-energy g-quanta absorber composition is of crucial importance. This is demonstrated in dependence of thermoluminescence on IR energy, especially in the area of photoelectric emission, i.e. in gamma impact energies lower than 200 keV. Fig. 1 shows the dependence of the mass absorption coefficients on the gamma-quanta energy for some materials [1]. Please cite this article in press as: Aluker N.L., Suzdaltseva, Ya.M., Herrmann M.E., Dulepova A.S. Thermoluminescent detectors for surveillance studies of radiation exposure of the population. Science Evolution, 2016, vol. 1, no. 2, pp. 3-10. doi: 10.21603/2500-1418-2016-1-2-3-10. Copyright © 2016, KemSU. This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International License (http:// creativecommons.org/licenses/by/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material for any purpose, even commercially, provided the original work is properly cited and states its license. This article is published with open access at http:// science- evolution.ru/ μ /ρ, cm /g μ /ρ, cm /g 2 2 0.1 Eγ, keV Fig. 1. Dependence of the mass absorption coefficients on the gamma-quanta energy for some materials [1]. Fig. 2. Energy dependences of the thermoluminescence yield on a logarithmic scale (with reference to 60Co) for different types of detectors [14]. Fig. 2 shows the energy dependences of the thermoluminescence yield on a logarithmic scale with reference to 60Co for detectors based on different luminophors. The X-axis is the energy; the Y-axis is the relative yield of TL-IЕ/ICo-60 Despite the undoubted merit (equivalence of human soft tissues), detectors made of LiF-based materials, used in personal dosimetry, have a number of significant disadvantages (spread in sensitivity within the lot, a number of thermoluminescence peaks, a complex multi- step heating mode, dose dependence superlinearity at doses of 0.1 Gy, hygroscopicity) [6, 7]. Currently, the range of materials used to produce these detectors, has expanded considerably. Depending on the dosimetry problem, it is expedient to apply the most appropriate type of detector (luminophor). In addition to LiF, fundamentally different classes of substances are currently considered as radiation- sensitive environments, the most important of which are wide-band oxide materials such as Al2 O3 , BeO, MgO, SiO2, and others [8-11, 13]. If you want to study the topography of radiation fields, used, for example, for exposure of semiconductor or ceramic components, it is advisable to use detectors with effective atomic number and element composition as close as possible to the irradiated material [14, 15]. i i If a luminophor has multiple traps in different depths (Е ), TL curve will have some peaks. Various thermoluminescence peaks may have different yield of luminescence, i.e., different probability of photon emission upon recombination, different luminescence spectral composition, which may lead to different luminescence registration efficiencies depending on the spectral sensitivity of the photodetector used. In this regard luminophors having single peak thermoluminescence curve, for example, α-Al O , SiO 2 3 2 (Fig. 3) have clear advantages over luminophors with a complex thermoluminescence curve, for example, LiF: Mg, Ti [13] (Fig. 4). However, single-peaked shape of the thermolumi- nescence curve does not indicate that recombination after the charge carriers release from a trap is carried out at one of the luminescence center, but indicates only that the charge carriers are released from the trap of a certain depth (Е ). The luminescence spectrum may have some bands asisociated with the recombination of carriers at different impurity or structural defects - luminescence centers. Experimental Part. Comparison of characteristics of different types of detectors Thermoluminescent method of dosimetry is used in 90% of all cases of individual radiation control of personnel working in contact with ionization sources worldwide. The advantages of thermoluminescent detectors (TLDs) are: high sensitivity to different types of radiation, integral accumulation of radiation doze, small dimensions and relatively low cost. Due to the small size of TLD, these detectors can be used to detect real topography of ionization fields, including medical application of ionization radiation, as well as for radioecology monitoring of areas exposed to radiation. It is necessary to use exactly the same dosimetric equipment and experimental conditions, and to compare results between the different types of detectors, to be Thermoluminescence Thermoluminescence 120 100 80 60 40 20 0 360 380 400 420 440 460 480 500 520 Temperature, K Fig. 3. Thermoluminescence curve of TLD-K detector (SiO2) at a heating rate of 2°С/sec (a). Fig. 4. Thermoluminescence curve of LiF: Mg, Ti under irradiation by 90Sr/90Y, dose 0.1 Gy, heating rate 1°С/sec (b). able to measure the advantages and disadvantages of different types of detectors. This work has used a modified dosimetric installation DTU-01M. The dosimetric characteristics of various thermoluminescent detectors (made from various materials by differentmanufacturers) weretestedandcomparedduring experiment. A range of detectors was tested, including LiF (USA), LiF (Stavropol, Russian Federation), LiF (China), TLD-100 (LiF, Irkutsk, Russian Federation), TLD-К (SiO2 Kemerovo, Russian Federation), TLD- 500 (Al2O3 ) (Sverdlovsk, Russian Federation), Ca3F, Table 1. Main parameters of the detectors used CaSO and detectors based on the silicon oxide mixed with nanodispersed diamonds (TLD-KAS (SiO 2, С)). TLD-KAS is a synthesized test prototype based on a 4 4 heterogeneous material composed of a luminophor with high luminescence yield, and diamond nanoparticles (varying the percentage of diamond nanoparticles results in variation of Zeff of the detector). A study of dosimetric characteristics was carried out. The test of the experimental material has demonstrated that the addition of diamond particles significantly increases the sensitivity range of the detector, which is important for industrial dosimetry. During the experimental work, the dimensions and volume of detectors were calculated. Slope coefficients of linear dependence on the radiation dose, and sensitivity of detectors and materials were calculated with reference to the DTG-04 detector (relative coefficients taking into account the volume of detector). Table 1 shows the main parameters (appearance, dimensions, peak temperature) of the detectors examined. Table 2 shows relative characteristics of different types of detectors based on different materials (LiF, Al2O3, SiO2 CaF2 CaSO4). Table 3 summarizes some characteristics of the detectors and conditions of their annealing and measurements (experimental and literature data). Table 4 shows literature data for sensitivity of some LiF-based detectors under various irradiation conditions TLD-K detectors have relatively wide detection range. Detector type Diameter, mm Thickness, mm Volume, mm3 Peak temperature, °С Appearance LiF (USA) 4.66 0.73 12.37 207 Non-transparent polycrystalline disk LiF (Stavropol, Russian Federation) 4.41 0.95 14.6 200 Non-transparent polycrystalline disk LiF (China) 4.58 0.75 12.2 200 Non-transparent polycrystalline disk LiF (Irkutsk, Russian Federation) 4.57 0.94 15.3 203 Transparent crystalline disk TLD-K(SiO2) 2.78 0.51 3.9 132 Semi transparent amorphous square TLD-500 (Al2O3 ) 5.04 0.85 17.0 171 Transparent crystalline disk CaF2 5.01 1.01 20.0 346 Non-transparent polycrystalline disk CaSO4 5.08 1.02 20.7 215 Non-transparent polycrystalline disk TLD-KAS (SiO2, С) 4.23 0.9 12.5 168 Non-transparent polycrystalline disk Table 2.Comparative characteristics of detectors Type Material Diameter Thickness V, mm3 Relative sensitivity coefficient (with reference to DTG-04) Relative coefficient (with reference to DTG-04) USA LiF 4.7 0.7 12 0.3 0.4 Stavropol LiF 4.4 1.0 15 0.3 0.3 China LiF 4.7 0.7 13 0.3 0.3 DTG-04 Irkutsk LiF 4.6 0.9 15 1.0 1.0 Kemerovo TLD-K SiO2 2.9 0.5 4 0.8 2.7 Ekaterinburg TLD-500 Al2O3 5.0 1.0 19 32 29 CaF2 CaF2 5.0 1.0 20 6 5 Tartu CaSO4 CaSO4 5.1 1.0 21 13 10 TLD-KAS SiO2 +С 4.2 0.9 13 0.03 0.03 Table 3. Characteristics of the detectors and conditions of their annealing and measurements (experimental and literature data) Detector type Material Annealing conditions Measurement conditions Dose equivalent mSv Repeatability, % Within-lot variation % ТLD-100 LiF - Mg, Ti 60 min at Т 400°С Prior heating to 100°С 0.042±0.008 4 23 ТLD-400 LiF - Mg, Ti 60 min at Т 400°С Prior heating to 100°С 0.040±0.004 5 27 DTG-4 LiF - Mg, Ti 60 min at Т 400°С Prior heating to 100°С 0.039±0.004 4 20 ТLD-1011 LiF - Mg, Cu, P 10 min at Т 240°С Prior heating to 60°С, 10 sec 0.004±0.002 6 24 TLD-500К Intrinsic defects Annealing at 400°С Linear heating <0.004 4 27 TLD-K Intrinsic defects Annealing at 400°С Linear heating <0.004 3 7 Table 4. Comparison of sensitivity of detectors (literature and experimental data) Type of detector Relative sensitivity 60Со 10 mm of absorber layer Relative sensitivity 60Со Relative sensitivity Cs-137 10 mm of absorber layer Relative sensitivity ТLD-100 0.40±0.02 0.40±0.02 0.41±0.02 0.41±0.03 ТLD-400 1.01±0.03 1.0±0.04 DTG-4 1±0.03 1.03±0.04 1±0.04 0.97±0.03 ТLD-1011 5.8±0.2 6.2±0.3 4.8±0.2 5.2±0.3 Fig. 5 shows the dose dependence of TLD-K detector on a logarithmic scale. The Co-60 MXP-20 source was used. Fig. shows that detector reliably measures doses in the range of up to 1 kGy. The slopes of the dose linear accumulation, i.e. sensitivity to photons of different energies are different. Exposure to gamma rays in MXP-20 (60Co source) has shown that the thermoluminescence intensity dose dependence maintains its linearity in the range of up to 1 kGy (Fig. 6). LiF-based detectors show deviation from the linearity at values near 0.1 Gy. TLD-500 detectors features a wider linearity range, but it is limited to 10Gy maximum. Thus, in the measurement of high doses, only TLD-K detectors allow high-dose measurements typical for radiation technologies. Dose measured by TLD-K detector, Gy Dose measured by TLD-K detector, Gy 10000 1000 100 10 1 1 10 100 1000 10000 100000 Radiation dose, Gy Fig. 5. Dependence of thermoluminescence yield on radiation dose a large dose range. 1000000 I, rel. unit I, rel. unit 100000 10000 1000 100 y(200 keV) = 1305x y(1250 keV) = 793x y(20 keV) = 3742x 0.1 1 10 100 1000 Dose, mGy Fig. 6. Dependence of thermoluminescence intensity on radiation dose during photon bombardment (in the energy range of photons of 0.2-1000 mGy). Practical dosimetry. Monitoring A great potential for application of TLD-Kdetectors is determined by the adequacy of determination of the absorbed dose rate in soils, sediments, Quaternary sediments, archaeological pottery and other quartziferous materials. It is currently used in the method thermoluminescent dating of archaeological finds and Quaternary sediments, as well as in appraisal survey and surveillance studies in geology and medicine [16-23]. Due to the high uniformity of characteristics, lack of light sensitivity, low cost, and chemical stability, detectors are also used for the territorial radioecological monitoring and large-scale individual dosimetric control of population by measuring the maximum absorbed dose in the bone tissue. Surveillance studies require a quantitative characteristic of the negative impact of human activity on the characteristics measured intheprocessofsurveillance. The major question is: “What is the contribution of man- made factor in the results obtained?” The direct answer is monitoring before and after certain activities. However, precedently, the monitoring was not carried out prior to the beginning of industrial activity. Therefore, analysis of the resultsuses “plausiblereasonings” based on acomparison of data for similar regions, theoretical estimates, intuitive notions, etc. It is therefore quite natural that the results are often not sufficiently reliable, and sometimes just wrong. Therefore, attempts to develop methods of environmental monitoring results processing, allowing to properly quantitative estimate of contribution of man-made factor in the results obtained. The fundamental possibility of solution is related to the following. Distribution of parameters in the absence of man-made factor is well described by the logarithmically normal distribution. The influence of man-made factor usually leads to distortion of this distribution. Thus, deviation value allow to get a conceptual idea of the role of man-made factor. Fig.s 7 and 8 shows the dose distribution during monitoring measurements. Gaussian is the natural radiation background caused by space radiation and radiation of naturally distributed radionuclides (without human influence). The most probable average value for Kemerovo Region for the monitoring period of five years and approximately 3,000 measurements is 0.3 ± 0.03cGy. The average values of natural background vary slightly for North (0.28) and South (0.32) of the region. The influence of man-made of other factors (e.g, elevated concentrations of radon) leads to distortion of the distribution (Fig. 8). Fig. 7. An example of the radiation exposure distribution at the territorial monitoring in Kuzbass (natural background in the absence of man-made impact). 40 Number of observations Number of observations 35 30 25 20 15 10 5 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 cSv/year 0.6 Tashtagol Leninsky district, Kemerovo Fig. 8. An example of the radiation exposure distribution at the territorial monitoring in Kuzbass (background with additional exposure). Radiation monitoring in propagation of the accident at the Fukushima nuclear power plant TLD-K detector registers the absorbed dose of mixed radiation with a lower limit of 100 μGy. When exposed to normal background this dose is accumulated for 12 days. After two-day dose accumulation (March 14 and 15), the absorbed dose was 200 ± 120 μGy. After four-day dose accumulation (from March 14 to 17), the absorbed dose was 170 ± 90 μGy, i.e. exponential decay was observed (see Fig. 9). Thus, on March 13 and 14, the maximum absorbed dose of mixed radiation in Kemerovo was 10 times higher than the normal background radiation exposure. This indicates that at the beginning of the accident propagation a radioactive cloud moved towards the Far East, China, and Siberia at a speed ensuring its passage over Kuzbass 2 days after the earthquake and tsunami. Medicine Currently, medical procedures and treatment modes involving the use of radioactivity are the main contributors to the man-made dose of radiation received by humans. Unlike other sources of radiation dose received by the population, this type of radiation exposure can and should be controlled with the aim of reduction or optimization taking into account the “risk- benefit” effect. This involves determination of radiation exposure to patients and staff, as well as workspace dosimetry, study of dose distribution over the radiation field by comparing the effect of using various devices and various treatments. TLD-K detectors are well-suited to solve the above problems. An example of usingTLD-K detectors to control the radiation dose during certain X-ray surgical procedures (coronary angiography, stenting) is shown in Fig. 11. The energy dependence of the detector sensitivity is similar to the bone tissue energy dependence, therefore, this detector measures the maximum absorbed dose in the bone tissue with no corrections. Dosimetry is conducted directly during fluoroscopy or certain X-ray surgical procedures ensuring the real working conditions during the procedure. According to preliminary information on the work of a physician during certain X-ray surgical procedures (coronary angiography, stenting), based on ~ 200 days a year and an average daily absorbed dose of ~ 100 mSv, medical staff receives an annual radiation exposure of 20 mSv, which is lower than the dose limit for Group A professionals. Hand doses are higher. Thyroid dose of patients was very high; ~ 6mSv per surgical procedure, and gonad dose was 60 μSv, i.e. 100 times less (Fig. 11). Excess above the normal average background, μR/h Excess above the normal average background, μR/h Dynamics of changes in the outside gamma background 5 4 3 2 1 0 13 15 17 19 21 Days, March Fig. 9. Dynamics of change in the radiation background measured by TLD-K detectors. 140 120 μGy μGy 100 80 60 40 20 0 The daily absorbed dose obtained by integrating for 2.4 days (March 13-15) (1), for 4 days (March 13-17) (2) and average for 10 days in normal background Row2 Row1 1 2 3 Fig. 10. Doses registered by TLD-K detectors. Radiation exposures to physician μSv μSv standard deviation average value stenting, procedure average and standard deviation coronary angiography, procedure average and standard deviation all day, left hand coronary angiography, left hand, for procedure Fig. 11. Radiation doses during certain X-ray surgical procedures (coronary angiography, stenting). Fig. 12. Average radiation exposures to organs of medical staff for working day and to patients’ thyroid. CONCLUSION Themainadvantagesof TLD-Kdetectors(amorphous SiO ) over similar devices is high homogeneity of therm2 oluminescent properties within the lot ofdetectors due to their physical and chemical structure - amorphous material. Therefore detectors grading by sensitivity necessary for all TLDs of monocrystalline material is not required. Thus, reliability of dosimetry increases and labor costs reduce. Detection limit for small doses is less and more reliable than for LiF-based detectors, currently used for Lack of sensitivity increases the reliability of the dosimetry. The detectors have a high chemical resistance to aggressive media, high mechanical strength, are not soluble in water and therefore can be used in vivo. Cost price of TLD-K (based on amorphous SiO2) is less than the cost of monocrystal detectors of domestic and foreign production. eff eff The developed TLD-KAS will allow to vary the effective atomic number of the detector (Z ), varying the nanodiamond content and tailoring it to Z of certain personnel monitoring. materials or human tissues. eff Registration limits (linear region) are higher than that of all existing domestic and foreign TLD detectors, which is of crue importance for technological dosimetry. This causes the preference for use of these detectors for the purposes of large-scale monitoring and process dosimetry compared to existing types of detectors.
Список литературы

1. Kurt A., Kahyaoglu T. Characterization of a new biodegradable edible film made from salep glucomannan. Carbohydrate polymers, 2014, vol. 104, pp. 50-58. doi:https://doi.org/10.1016/j.carbpol.2014.01.003.

2. Oliviero M., Sorrentino L., Cafiero L. Foaming behavior of bio-based blends based on thermoplastic gelatin and poly (butylene succinate). J. of Appl. Polymer. Science, 2015, vol. 132, no. 48, pp. 2290-2298. doi:https://doi.org/10.1002/app.42704.

3. Volkov V.S. Anizotropiya v nelineynoy reologii polimerov [Anisotropy in nonlinear polymer rheology]. Vysokomolekulyarnye soedineniya [Macromolecular compounds], 2014, vol. 56, no. 5, pp 575-581. doi:https://doi.org/10.1134/S0965545X14050162.

4. Ol'khov A.A, Gol'dshtrakh M.A., Ishchenko A.A., Iordanskiy A.L. Obrazovanie kompleksov v smesyakh na osnove poligidroksibutirata i polietilenglikolya [Formation of complexes in mixtures based on polyethylene glycol and polyhydroxybutyrate]. Khimicheskaya fizika [Chemical physics], 2015, vol. 34, no. 11, pp. 63-72.

5. Prosekov A.Yu., Ul'rikh E.V., Babich O.O., Dyshlyuk L.S. Issledovanie koeffitsienta integral'nogo svetopropuskaniya i tolshchiny plenok iz farmatsevticheskogo zhelatina i ego rastitel'nykh analogov [Studies of the integral light transmittance and thickness of films from the pharmacetical gelatin and its plant analogs]. Fundamental'nye issledovaniya [Fundamental studies], 2014, no. 9, pp. 2411-2415.

6. Korotkaya E.V., Prosekov A.Yu. A method for producing a collodion film by centrifugal Patent, no. 2011109728/052011, 2012.

7. Slivkin A.I., Belenova A.S., Shatalov G.V. Izuchenie svoystv rastvorov khitozana [Studying of chitosan solutions properties]. Vestnik Voronezhskogo gosudarstvennogo universiteta, Seriya: Khimiya. Biologiya. Farmatsiya [Bulletin of Voronezh State University Series: Chemistry. Biology. Pharmacy], 2014, no. 1, pp. 134-137.

8. Prosekov A.Yu., Ul'rikh E.V., Babich O.O., Sukhikh S.A. Reologicheskie svoystva rastitel'nykh analogov farmatsevticheskogo zhelatina [Rheological properties of plant analogues of pharmaceutical gelatin]. Fundamental'nye issledovaniya [Fundamental studies], 2013, no.10-15, pp. 3384-3388.

9. Chursin V.I. Reologiya organovodnykh rastvorov biopolimera i kharakteristika plenok [Rheology of organowater biopolymer solutions and feature of films]. Dizayn i tekhnologii [Design and technology], 2012, vol. 28., no. 70, pp. 52-58.

10. Ahmed J., Hiremath N., Jacob H. Antimicrobial, Rheological, and Thermal Properties of Plasticized Polylactide Films Incorporated with Essential Oils to Inhibit Staphylococcus aureus and Campylobacter jejuni. J. of Food Science, 2016, vol. 81, no. 2, pp. 419-429. doi:https://doi.org/10.1111/1750-3841.13193.

11. Amonova D.M., Mukhamedzhanova M.Yu., Shomurotov Sh.A., Turaev A.S. Reologicheskie svoystva kontsentrirovannykh vodnykh rastvorov gidrolizovannykh proizvodnykh galaktomannana [Rheological properties of concentrated aqueous solutions of hydrolysed galactomannan derivatives]. Khimiya rastitel'nogo syr'ya [The Chemistry of Plant Raw Materials Academic Journal], 2014, no. 4, pp. 67-75.

12. Mantia La F.P., Mistretta M.C., Palermo S. Morphology, rheology, and mechanical properties of a new nanobiocomposite.

13. J. of Appl Polymer Science, 2015, vol. 132, no. 25, pp. 1829-1839. doi:https://doi.org/10.1002/app.42128.

14. Mikesova J., Hasek J., Tishchenko G. Rheological study of chitosan acetate solutions containing chitin nanofibrils.

15. Carbohydrate polymers, 2014, vol. 112, pp. 753-757. doi:https://doi.org/10.1016/j.carbpol.2014.06.043.

16. Swain S.K., Patra S.K., Kisku S.K. Study of thermal, oxygen-barrier, fire-retardant and biodegradable properties of starch bionanocomposites. Polymer composites, 2014, vol. 35, no. 7, pp. 1238-1243.

17. Ferrarezi F.M.M., Rodrigues G.V., Felisberti M.I. Investigation of cellulose acetate viscoelastic properties in different solvents and microstructure. European Polymer J., 2013, vol. 49, no. 9, pp. 2730-2737.

18. Asyakina L.K., Prosekov A.Yu., Ul'rikh E.V., Belova D.D. Issledovanie degradatsii plenok i kapsul iz rastitel'nykh analogov farmatsevticheskogo zhelatina [Study of degradation of films and capsules plant analogs pharmaceutical gelatine]. Fundamental'nye issledovaniya [Fundamental studies], 2014, no. 9, pp. 2369-2374.


Войти или Создать
* Забыли пароль?